Upgrade #11551
closedRegional-data-collection-portlet patch on production Gateways
100%
Description
CITE/UoA in the context of BlueBRIDGE WP5 RDB asked to deploy this patch on production asap to fix the incident #11459
Updated by Massimiliano Assante about 7 years ago
- Priority changed from Normal to Urgent
Updated by Massimiliano Assante about 7 years ago
Vassilis Floros wrote:
I submitted a remote build against 4.10. You can download the war from here:
Updated by Massimiliano Assante about 7 years ago
- Status changed from Planned to In Progress
Updated by Massimiliano Assante about 7 years ago
- % Done changed from 0 to 100
The portlet was hot deployed successfully but it returns an error: Persistence error on UserReference creation
https://bluebridge.d4science.org/group/wecafc-firms/regional-data-collections
here's the log.
[PORTAL] 1277668512 [http-bio-9090-exec-194] INFO gr.cite.bluebridge.endpoint.EndpointManager - Initiliazing Endpoint Manager with refresh interval 180 minutes [PORTAL] 1277668513 [http-bio-9090-exec-194] INFO gr.cite.bluebridge.endpoint.EndpointManager - Returned 1 service endpoint(s)
Perhaps requires web server restart? @vfloros@cite.gr @dkatris@di.uoa.gr
Updated by Vassilis Floros about 7 years ago
I think you are viewing this error in the UI. Please, can you clear your cahce and refresh the page? Does it appear again?
We are performing tests on the portlet right, now. It seems to work fine but give us some more time to repeat the whole process 2 or 3 times and confirm everything is OK.
Updated by Vassilis Floros about 7 years ago
The issue that caused the error to appear in the UI is resolved.
The service was redeployed, the portlet was tested again and it works as required.
Thank you for the collaboration.
Updated by Massimiliano Assante about 7 years ago
- Status changed from In Progress to Completed